TDK Banner
PDF DOCUMENTS

FEATURES
• Universal 85 - 265Vac Input Continuous, single phase, 47/63Hz
• Active Power Factor Correction 0.99
• Built in RS232/RS485
• Front panel lock
• Last Setting Memory
• High Resolution 16 bits ADCs & DACs
• Reliable Encoders for Voltage and Current Adjustment
• Parallel Operation with Active Current Sharing
• Independent Remote ON/OFF and Remote Enable/Disable
• External Analog Programming and Monitoring
• Reliable Modular and SMT Design
• 19" Rack mounted
• Five Year Warranty
• Optional Isolated Analog Programming and Monitoring
• Optional built-in GPIB (SCPI) Interface
• Optional built-in LXI Compliant LAN interface
• Optional built-in USB interface
• Optional Multi-Drop IEEE interface and Optional Multi-Drop (RS-485) Slave Interface
LabView® drivers/GUI
• Worldwide Safety Agency Approvals
• CE Mark for LVD and EMC Regulation
• Parallel Operation with Active Current Sharing

OTHER SOLUTIONS
• LOWER POWER
GenH
• HIGHER POWER
Gen3.3k
 
GENESYS™
Genesys 750W and 1.5kW, up to 200A
New 50V 1500W Model
Click here to request more Genesys 1U Information

The Genesys™ family of programmable power supplies sets a new standard for flexible, reliable, AC/DC power systems in OEM, Industrial and Laboratory applications. Now available in more power levels (750W, 1.5kW, 3.3kW, 5kW, 10kW and 15kW) and with output voltages from 7.5 to 600V, and current up to 1,000A. Active PFC, and universal input head a long list of standard features.

In addition to highest power density, for the first time a universal input is available in this size and power. The wide range input is not just dual range, but continuously variable from 85-265VAC, single phase, 50/60Hz. It also features Active Power Factor Correction of 0.99 at full load, another first in this size and density. This assures operation in difficult AC environments and meets European EMC requirements.

The user-friendly front panel provides reliable control through encoders selectable for fine or course adjustment (6 or 30 turns) and four digit LED Voltage and Current meters. Adjustable OVP, UVL and Current Foldback provide further flexibility. Their set values may be previewed on the front panel display. The Foldback may be set to latch output off if desired for safety.

New Interface Options
The newest option in the Genesys™ family is an LXI Certified LAN Interface. Features include Fast Start-up, Fixed and Dynamic Addressing and LAN Fault Detectors. A LAN equipped Master can also communicate with MD Option equipped Slaves. The interface is compatible with most standard Networks.

Genesys™ 750/1500W includes several other important new features and options. Up to four like units may be connected in parallel and user configured for the Master to Program and Monitor the total current of the group. Thus, four units can appear as a single 3/6kW power supply, increasing flexibility for system designers.

In the Digital Options, a new option called Multi-Drop allows an IEEE Multi-Drop Master to control Multi-Drop equipped Slaves over RS-485, avoiding the cost of a GPIB board in every slave power supply. Up to 31 may be addressed over the RS-485 lines of Master and Slaves.

Significant safety features include Safe Re-Start and Last Setting Memory. With Safe Re-Start, the user can select whether the Genesys™ power supply returns to previous settings after power off, or returns to zero (safe) output, waiting for user instructions. Last Setting Memory retains settings of output voltage and current, remote or local mode, OVP and UVL, Foldback, Baud Rate and Start Up Mode, without battery. Front Panel controls also include Output On/Off and Local/Remote selection. The Front Panel may be locked locally or by software command.

Like other Genesys™ products, the 1U 750/1500W includes standard, embedded 16 bit RS232/RS485 digital interface. Through this digital interface up to 31 power supplies may be controlled in daisy chain over the RS485 line. Analog remote programming is user selectable 0-5V or 0-10V via DIP switches on the rear panel. The design of Genesys™ power supplies is highly modular to offer short lead times. SMT technology provides high reliability.

Digital and isolated analog interfaces are optional. The optional IEEE digital interface is IEEE488.2 & SCPI compliant. Labview Drivers are available. Isolated analog programming options include either 0-5V & 0-10V or 4-20ma control.

Specifications
AC Input
All models: 85-265 VAC continuous single phase, 47-63 Hz
AC Line Current (100/200VAC):
750W - 10.5A/5A
1500W - 21A/11A
Active PFC (0.99)

Output Characteristics
Regulation: 0.01% + 2mV line/load (cv)
0.01% + 2mA line (cc)
0.01% + 5mA load (cc)

Protective Features
Adjustable OVP, UVL
Adjustable Current Foldback
Over-temperature
Safe/Auto Start

Programming
0-5V, 0-10V User Selectable via DIP Switch RS232/RS485 Standard

Mechanical
Size:
All models 19" W x 1 3/4" H x 17" D
Weight:
750W - 15.4lbs/7kg
1500W - 18.7lbs/8.5kg

Outline Drawings(PDF):
Gen1U 750W
Gen1U 1500W

Options (Factory installed, Embedded)

Multi-Drop Options
• IEEE (MD) Master P/N: IEMD
Controls MD slaves via RS-485
• MD Slave P/N:
MD Accepts commands over RS-485 from IEEE Master. Reduces cost vs. individual IEEE options.

Interface Options
• Isolated Analog Program/Monitor
Allows operation with floating references and in harsh electrical environments.
IS510 - 0-5V & 0-10V User Selectable
IS420 - 4-20mA USB LAN - LXI Certified
• USB
• LAN - LXI Certified

All specifications subject to change without notice.
Standard Model Listing
Model Number

Rated Power
(Watts)

Output
Voltage
(Volts)

Output
Current
(Amps)

Ripple mV RMS
(5Hz-1MHz)

Noise p-p
(<20MHz)

GEN 6-100
GEN 6-200
600
1200
0-6 0-100
0-200
8 60
GEN 8-90
GEN 8-180
720
1440
0-8 0-90
0-180
8 60
GEN 12.5-60
GEN 12.5-120
750
1500
0-12.5 0-60
0-120
8 60
GEN 20-38
GEN 20-76
760
1520
0-20 0-38
0-76
8 60
GEN 30-25
GEN 30-50
750
1500
0-30 0-25
0-50
8 60
GEN 40-19
GEN 40-38
760
1520
0-40 0-19
0-38
8 60
GEN 50-30 1500 0-50 0-30 8 60
GEN 60-12.5
GEN 60-25
750
1500
0-60 0-12.5
0-25
8 60
GEN 80-9.5
GEN 80-19
760
1520
0-80 0-9.5
0-19
8 80
GEN 100-7.5
GEN 100-15
750
1500
0-100 0-7.5
0-15
8 80
GEN 150-5
GEN 150-10
750
1500
0-150 0-5
0-10
12 100
GEN 300-2.5
GEN 300-5
750
1500
0-300 0-2.5
0-5
20 120
GEN 600-1.3
GEN 600-2.6
780
1560
0-600 0-1.3
0-2.6
60 300
Ordering Information
GEN 60 - 25 - - U
Model Voltage   Current   Factory Options   Line cord (750W only)
IEMD
MD
IS510
IS420
LAN
USB
 
© Copyright 1999-2009 TDK-Lambda Americas Inc. All rights reserved. Legal Information