TDK Banner
DOWLOADS
DOWNLOADS

FEATURES
• Built in RS-232/RS-485
• Standard Multi-Drop (RS-485) Slave Interface
• Global Commands for
RS-232/RS-485
• Last Setting Memory
• High Resolution 16 bit ADC's & DAC's
• Continuous Encoders for Voltage and Current Adjustment
• Parallel Operation with Active Current Sharing and Current Sum
• Independent Remote ON/OFF and Remote Enable/Disable
• Remote Analog Programming and Monitoring
• Reliable Modular and SMT Design
• 19" Rack mounted
• Optional built-in LXI Compliant LAN interface
• Optional built-in IEEE interface
• Optional built-in Isolated Analog Programming
LabView® Drivers/GUI
• Worldwide Safety Agency Approvals
• CE Mark for LVD and EMC Regulation
• Five Year Warranty

OTHER SOLUTIONS
GENH-1U (750W)
GEN-1U (750W/1.5kW)
GEN-1U (2.4kW)
GEN-2U (3.3kW)
GEN-2U (5.0kW)
GEN-3U (10kW)
ESS (10kW/15kW)
EMHP (15kW-90kW)
 

Genesys™ 3U 15kW Programmable DC Power Supply
Outputs from 30V (@500A) to 1500V (@10A)
Click here to request more Genesys™ 3U 15kW Information


  • Overview
  • Technical Details
  • Downloads
  • Technical Support

Product Overview and Models

The Genesys™ 3U Full-Rack (GEN-3U) series of 15kW DC Programmable Power Supplies provides high power density (up to 15kW) with a complete set of user-friendly interfaces within a 3U profile.

This series offers Output voltages from 30V (@ 500A) to 1500V (@ 10.0A) in a Three-phase 208VAC Input (180-253VAC, 47-63Hz), a Three-phase 400VAC Input (342-440VAC, 47-63Hz) and a Three-phase 480VAC Input (432-528VAC, 47-63Hz) all with Passive Power-Factor Correction (0.88 @ rated load).

Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.

All models are CE Marked in accordance with the Low Voltage and EMC Directives, are RoHS compliant, have worldwide Safety Agency approvals (UL/cUL 60950-1 and EN 60950-1 recognized) and offer a five (5) year Warranty.

Model Number

Rated Power
(Watts)

Output
Voltage
(Volts)

Output
Current
(Amps)

Ripple mV RMS
(5Hz-1MHz)

Noise p-p
(<20MHz)

Efficiency
%
(100/200VAC)

Datasheet

Buy Online

GEN 30-500 15000 0-30 0-500 20 60 88
GEN 40-375 15000 0-40 0-375 20 60 88
GEN 50-300 15000 0-50 0-300 20 75 88
GEN 60-250 15000 0-60 0-250 20 75 88
GEN 80-187.5 15000 0-80 0-187.5 25 100 88
GEN 100-150 15000 0-100 0-150 25 100 88
GEN 125-120 15000 0-125 0-120 25 100 88
GEN 150-100 15000 0-150 0-100 25 150 88
GEN 200-75 15000 0-200 0-75 35 175 88
GEN 250-60 15000 0-250 0-60 35 200 88
GEN 300-50 15000 0-300 0-50 60 200 88
GEN 400-37.5 15000 0-400 0-37.5 60 300 88
GEN 500-30 15000 0-500 0-30 60 350 88
GEN 600-25 15000 0-600 0-25 60 350 88
GEN 800-18.8 15000 0-800 0-18.8 80 700 93.5
GEN 1000-15 15000 0-1000 0-15 100 800 93.5
GEN 1250-12.0 15000 0-1250 0-12.0 120 1000 93.5
GEN 1500-10.0 15000 0-1500 0-10.0 140 1400 93.5

 

Ordering Information (30 to 600V Models)

Model

Voltage

 

Current

 

Factory Options

 

AC Input

GEN

60 - 250 - LAN - 3P208
          IEMD   3P400
          USB   3P480
          IS510    
          IS420    

Ordering Information (800 to 1500V Models)

Model

Voltage

 

Current

 

Factory Options

 

AC Input

GEN

60 - 250 - LAN - 3P208
          IEMD   3P400
          USB   3P480
          IS420    

 

The Genesys™ family of programmable AC/DC power supplies sets a new standard for flexible, reliable power systems in OEM, Industrial and Laboratory applications. Now available in more power levels (750W, 1.5kW, 2.4kW, 3.3kW, 5kW, 10kW and 15kW) and with output voltages from 7.5 to 1500V and current up to 1,000A. Power Factor Correction, Standard RS-232/RS-485 interface and world-wide AC inputs head a long list of standard features.

This member of the Genesys™ product family of programmable switching power supplies provides high power density, low Output voltage ripple and a complete set of user-friendly interfaces. In addition to high power density, popular worldwide three phase inputs are available. AC inputs are available for 208VAC, 400VAC or 480VAC - three phase, 50/60Hz with Passive Power Factor Correction. This assures operation in difficult AC environments to meet European EMC requirements.

A user-friendly front panel provides reliable control through digital encoders selectable for fine or coarse adjustment (~6 or 30 turns) and four digit LED Voltage and Current meters. Adjustable OVP, UVL and Current Foldback protection features provide further flexibility and their set values may be previewed on the front panel display, even with the Output Off. The Foldback may be set to latch the Output off if desired.

All Genesys™ platforms include several other important system and safety features. 

Up to four like units may be connected in parallel and user configured for the Master unit to Program and Monitor the total current of the group. Thus, four units can appear as a single 3kW to 60kW power supply, increasing flexibility for system designers.

Significant safety features include Safe Re-Start and Last Setting Memory. With Safe Re-Start, the user can select whether the Genesys™ power supply returns to previous settings after power off, or returns to zero (safe) output, waiting for user instructions. Last Setting Memory retains settings of output voltage and current, remote or local mode, OVP and UVL, Foldback, Baud Rate and Start-Up Mode, without battery backup. Front Panel controls also include Output On/Off and Local/Remote Digital selection. The Front Panel may be locked locally or by software command.

All Genesys™ products include a standard, embedded 16 bit RS-232/RS-485 Digital interface. Through this Digital interface up to 31 power supplies may be controlled in a daisy-chain over a RS-485 digital communication bus. Remote Analog programming is user selectable (0-5V or 0-10V) via DIP-switches on the rear panel.

Among standard digital features, Multi-Drop allows an IEEE or LAN Master unit to control standard Slave units over the RS-485 digital communication bus, avoiding the cost of a GPIB or LAN interface in every Slave power supply. Up to 31 power supplies may be addressed over the RS-485 digital communication bus.

Interface Options
Digital and Isolated Analog interfaces are optional, factory installed (one per power supply).

Optional LXI Certified LAN Digital Interface, (LAN), is SCPI compliant. Standard features include Fast Start-up, Fixed and Dynamic Addressing and LAN Fault Detectors. A LAN equipped Master unit can also communicate with standard Slave units over a RS-485 digital communication bus, and is compatible with most standard Networks.

Optional GPIB Digital Interface, (IEMD), is IEEE488.2 & SCPI compliant.

Isolated Analog programming options include either 0-5V & 0-10V (user selectable) or 4-20ma control.

Safety agency approvals include UL/cUL 60950-1 and EN60950-1.

All models are CE Marked and offer five (5) year Warranty.

For more information about the Genesys™ AC/DC Programmable Power Supply Series, contact the TDK-Lambda Americas High Power Division directly at +1-732-922-9300 or online at - http://www.us.tdk-lambda.com/hp/sales_html/cont_saless.htm, or contact your local Sales representative (http://www.us.tdk-lambda.com/hp/sales_html/us_representatives.htm).

A wide range of other TDK-Lambda High Power Division Low Voltage and High Voltage power supplies can be viewed from the website: http://us.tdk-lambda.com/hp/

Specifications

AC Input
Three phase 208VAC
180-253VAC 47-63 Hz, PF=0.88
Imax=64A

Three phase 400VAC
342-440VAC
47-63 Hz, PF=0.88
Imax=32A

Three phase 480VAC
432-528VAC 47-63 Hz, PF=0.88
Imax=27A

Output Characteristics
Regulation (Line) - CV:
Line 0.1% VOmax < 30V (CV)
Line 0.01% 30V <= VOmax < 600V (CV)
Line 0.05% 600V < VOmax < 1500V (CV)

Regulation (Load) - CV:
Load 0.1% VOmax < 30V (CV)
Load 0.02% 30V <= VOmax <= 600V (CV)
Load 0.1% 600V < VOmax < 1500V (CV)

Regulation (Line) - CC:
Line 0.1% IOmax => 333A (CC)
Line 0.05% 25A < IOmax < 333A (CC)
Line 0.2% IOmax < 25A (CC)

Regulation (Load) - CC:
Load 0.1% IOmax => 333A (CC)
Load 0.075% 25A < IOmax < 333A (CC)
Line 0.2% IOmax < 25A (CC)

 

Protective Features
Adjustable OVP, OCP, UVL
Adjustable Current Foldback (FOLD)
Over-temperature (OTP)
Safe/Auto Start
Front Panel Lock
Phase Loss Detect

Programming
0-5V, 0-10V User Selectable via DIP-switch
RS-232/RS-485 Standard
Parallel Master/Slave setting reports total current of up to four units connected in parallel

Mechanical
Size: (Models with Vout <=600V)
19" W x 3U (5.25") H x 25.5" D (max)
Weight: 97lbs/43kg

Size: (Models with Vout >600V)
19" W x 3U (5.25") H x 24.9" D (max)
Weight: 70lbs/32kg

Outline Drawings
2D Drawings - PDF (30-50V models)
2D Drawings - PDF (800-1500V models)
2D Drawings - PDF (All other models)

Interface Options (one per unit)
(factory installed, embedded)
• LAN: LXI certified (Class C)
• IEMD: IEEE 488.2 & SCPI compliant
• USB (2.0 compliant)
• Isolated Analog Program/Monitor
o IS510: 0-5V & 0-10V (user-selectable)
o IS420: 4-20mA

All specifications subject to change without notice.
Factory Technical Support Contacts

Low Voltage Products - 6V to 1500V
(Genesys(TM), ESS, EMHP, EMS, TCR etc, and other models with less than 600V outputs)
Support Hours 8am-4.30pm Eastern
Standard Time
Jeff Bush - Email
Tel: (732) 922 9300 x209
Fax: (732) 922 1441
 
© Copyright 1999-2017 TDK-Lambda Americas Inc. All rights reserved. Legal Information