The LC Series are a new design of compact
water cooled power conditioning solutions for high performance HV
Capacitor Charging applications requiring extremely low pulse to
pulse repeatability. The LC1202 capacitor charging power supply is
capable of delivering peak output charge rates of 13.5kJ/sec and
average rates of 12kJ/sec. If used for DC applications the unit can
continuously deliver 15kW power (12kW with 208VAC input). The unique phase shifting inverter
design enables the supply to charge capacitive loads with shot to
shot voltage repeatability of 0.1% or better at repetition rates up
to 1kHz. The
LC1202 shares elements of its topology with the XR series, but
utilizes a brand new design of water cooled phase shifting resonant
inverter. The use of a unique sealed water cooled HV tank assembly
results in an 12kJ/second power supply in the same footprint as a
standard 8kJ unit. The sealed HV tank also allows the unit to
operate when the supply is not completely horizontal, unlike conventional oil insulated high
voltage power supplies. Since the LC series does not require
external air for cooling it is particularly suitable for
installation in tight spaces, or in adverse environments. TDK-Lambda Americas
is the only company currently offering this advanced performance in
a compact 12kJ/sec water cooled package. |
AC Input
208 VAC or 400 VAC or 480 VAC,
3 phase, 50/60 Hz.
Field selectable with appropriate conversion kit 208/400
(VAC versions only).
(Please specify at the time of order).
Average Charging Rate
12,000 J/s at rated Output Voltage.
Peak Charging Rate
13,500 J/s at rated Output Voltage.
Standard Voltage Ranges
1, 1.5, 2, 3, 4, 5, 6,
10, 15, 20, 30 kV.
All models continuously variable from 0 to 100% of rated voltage output.
Linear to within 1% of full scale. Accuracy 1% of rated.
Polarity
Available as fixed Positive or
Negative, Please Specify.
High
Voltage Assembly
Sealed silicone oil Insulated HV section with zero air.
Output
Connector/Cable
| Output
Voltage |
Connector |
Cable |
| 1-30kV |
Proprietary |
DS 2214SSJ |
Input
Connector
VDE, UL, CSA, approved.
Power
Factor
Passive PFC 0.85 min
Efficiency
Better than 85%
Stored
Energy
Less than 0.3 Joules all models.
Stability
0.2% per hour after 1 hour
warm-up.
|
Cooling
Flowed water at 2US GPM (7.6L/min) max. inlet temperature 35 oC.
All water paths are at ground potential and are copper, brass or
hydraulic hose. Connections via 12mm pipe to standard Swagelok type
fittings on back of unit.
Pulse to
Pulse Repeatability
+/- 0.1% to 250Hz standard.
+/- 0.1% to 1kHz option.
Temperature
Coefficient
100 PPM per oC
Ambient
Temperature
Storage: -40 to +80 oC
Operating:5 to +45 oC
Humidity
10-90% Non-condensing
Protection
The power supply is protected against open
circuits, short circuits, overloads and arcs.
Agency
Approvals
Certification to EN60950 (pending)
Mechanical
19"(482mm) x 17"(432mm) x 8.75"(222mm)
Click here for sketch (PDF)
Accessories
- Detachable 10 foot HV cable
- Operating manual
Remote Control
Via 25pin d-type connector on rear panel. Click
here for details
Options
| Suffix-5V |
0 to
+5 volt program (0 to full-scale output) |
| Suffix-LP |
Latching
overload protection |
| Suffix-RS |
Remote
sense |
| Suffix-CT |
Optional
internal contactor for OEM only (standard on L/S
models) |
|