Repeatability < 0.1% at rep. rates to 2kHz
Minimum stored energy 
Ultra fast command charge timing cycle 
Unlimited parallel capability for higher power 
Remote sense input
Remote compatibility with 802 and 402 
Output voltage to 50kV 
TUV safety approved

Applications

Excimer Lasers
Pulsed YAG Lasers
Lithotriptors
Precipitators
General Medium Power PFN's
Grid Bias Supplies
N2 Lasers
Dye Lasers
TEA Lasers

Other Solutions
Lower Power 402
Higher Power 802

Downloadable Manual in PDF Format (less schematics)

App. Notes
APP Note 500: Calculating Capacitor Charge Time
APP Note 502: Calculating AC Line Currents
APP Note 505: Charging units as Continuous Output DC  Supplies
APP Note 507: Charging Large Load Capacitors
APP Note 509: What is Regulation and Repeatability?
APP Note 513: Power Factor Correction
APP Note 517: Protection Against Voltage Reversal
Appn. Questionnaire

Get Acrobat Reader

 

Page last updated: Tuesday, April 01, 2008

Click here to go to the home page ALE Systems logo




Have a question?

ALE XR/XRDC Series. 1-30 kV, 6000J/sec
8,000W DC

The XR Series are low cost solutions for high performance HV Capacitor Charging applications offering extremely low pulse to pulse repeatability. The XR-DC allows continuous DC operation with low ripple, and low stored energy. Employing TDK-Lambda Americas patented phase shifting parallel resonant converter topology the XR series supplies offers unrivalled pulse to pulse repeatability at extreme repetition rates. Unlike other manufacturers who claim high performance in data sheets, the XR series has demonstrated 0.1% pulse to pulse repeatability at repetition rates to 2kHz, in real field applications.

The XR802 shares many features with the standard 802, but in addition it is equipped with a phase shifting resonant inverter configuration which allows the charging current to be gradually reduced as the load voltage approaches the programmed level. This feature allows the XR802 supply to repetitively charge capacitive loads with pulse to pulse repeatability of 0.1% or better at repetition rates of 1kHz or more. This is a particular requirement of high performance systems where charge voltage variability results in process or dose variability and a reduction in process quality. TDK-Lambda Americas is the only power supply manufacturer currently offering this advanced performance in a compact 8kJ/sec air cooled package.


Specification
AC Input
208 VAC or 400 VAC, 
3 phase, 50/60Hz.
(Please specify at the time of order).

Average Charging Rate
6000 J/s at rated Output Voltage.

Peak Charging Rate

7000 J/s at rated Output Voltage.

Standard Voltage Ranges
1, 1.5, 2, 3, 4, 5, 6, 
10, 15, 20, 30 kV.
All models continuously variable from 10 to 100% of rated voltage output.
Linear to within 1% of full scale. Accuracy 1% of rated.

Polarity
Available as fixed Positive or Negative, Please Specify.

High Voltage Assembly
Oil Insulated HV section with optional air insulation at voltages below 6kV

Output Connector/Cable

Output Voltage Connector Cable
1-6kV  Amphenol HN RG-8/U
>6kV Proprietary DS 2214SSJ

Input Connector
VDE, UL, CSA, approved.

Power Factor
Passive PFC 0.85 min

Efficiency

Better than 85%

Stored Energy
Less than 0.3 Joules all models.

Stability
0.2% per hour after 1 hour warm-up.

Pulse to Pulse Repeatability
+/- 0.1% to 250Hz standard. 
+/- 0.1% to 1kHz option. 

Temperature Coefficient
100 PPM per oC

Ambient Temperature
Storage: -40 to +80 oC
Operating:0 to +45 oC

Humidity

10-90% Non-condensing

Protection
The power supply is protected against open circuits, short circuits, overloads and arcs.

Agency Approvals
Certification to EN60950 (pending)

Mechanical
19"(482mm) x 17"(432mm) x 8.75"(222mm)

Accessories
- Detachable 10 foot HV cable
- Operating manual

Remote Control
Via 25pin d-type connector on rear panel. Click here for details

Options

Suffix-5V 0 to +5 volt program (0 to full-scale output)
Suffix-LP Latching overload protection
Suffix-RS Remote sense
Suffix-CT Optional internal contactor for OEM only (standard on L/S models)

Ordering Information
XR802 L/S/OEM - 1kV - POS - 208VAC - XX